{"id":1494,"date":"2026-11-05T14:48:46","date_gmt":"2026-11-05T18:48:46","guid":{"rendered":"https:\/\/www.masterfluids.com\/blog\/?p=1494"},"modified":"2026-11-05T14:48:48","modified_gmt":"2026-11-05T18:48:48","slug":"how-to-test-metalworking-fluid-health-using-ph-conductivity-and-microbial-counts","status":"publish","type":"post","link":"https:\/\/www.masterfluids.com\/blog\/2026\/11\/05\/how-to-test-metalworking-fluid-health-using-ph-conductivity-and-microbial-counts\/","title":{"rendered":"How To Test Metalworking Fluid Health Using pH, Conductivity, and Microbial Counts"},"content":{"rendered":"\n<p>Most coolant sumps give plenty of warning before they fail. The pH slides a few tenths over three weeks, conductivity creeps upward after every top-off, and a dip slide that used to come back clean starts showing colonies. By the time anyone notices a rotten-egg smell on Monday morning or rust spotting on finished parts, the fluid has usually been in trouble for a while, and the cheapest window to fix it has already closed.<\/p>\n\n\n\n<p>Testing metalworking fluid health with concentration, pH, conductivity, and microbial counts exists to catch that drift while it is still a small adjustment. A disciplined testing routine protects tool life, surface finish, and in-process corrosion protection, and it keeps operators working in cleaner, more comfortable fluid. It also has a direct line to cost: every extra week a sump stays in specification is a week without a dump, a clean-out, a disposal invoice, and a fresh charge of concentrate.<\/p>\n\n\n\n<p>This guide walks maintenance teams through what each test actually measures, how often to take readings, how to read changes over time, and the point at which a shop test stops being enough and a laboratory sample becomes the right call.<\/p>\n\n\n\n<h2>Start With Concentration, Because Every Other Reading Depends on It<\/h2>\n\n\n\n<p>pH, conductivity, and microbial counts are hard to interpret without knowing the concentration of the fluid you are testing. A sump running two points lean will usually show a lower pH, weaker bacterial resistance, and poorer corrosion protection, while a sump running rich can raise pH and alkalinity enough to irritate skin and leave heavier residues on machines. Master Fluid&#8217;s Technical Services Laboratory estimates that<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/faqs.php\"> well over 80% of the trouble calls it receives trace back, directly or indirectly, to poor concentration control<\/a>, which is why concentration belongs at the top of every test sheet.<\/p>\n\n\n\n<p>Most shops check concentration with a handheld refractometer. The reading on the scale is a refractive index, and it only becomes a percentage once you multiply it by the product&#8217;s refractometer factor, which is listed on each product label and the <a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/data-sheets.php?catid=Support&amp;brand_cat=Support&amp;limit=brand\">product data and information sheet<\/a>. Refractometers are fast and inexpensive, but emulsified tramp oil and dissolved contaminants also bend light, so an aging sump can read higher than its true active concentration. When refractometer readings and machining performance stop agreeing, a<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/products\/show-category.php?catid=C48C\"> <\/a><a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/products\/show-category.php?catid=C48C\">titration kit<\/a> measures the chemistry itself and gives a more reliable number.<\/p>\n\n\n\n<p>Concentration also explains a lot of what happens between tests. Water evaporates from the sump with the heat of cutting and grinding, so topping off with the wrong mix slowly pushes concentration upward. Master Fluid&#8217;s guidance is to make up with a leaner mix than the operating concentration, and the<a href=\"https:\/\/apps.masterfluids.com\/makeup\/?r=NA\"> Coolant Makeup Calculator<\/a> works out the right ratio for a given sump.<\/p>\n\n\n\n<h2>pH Testing: What It Tells You About Metalworking Fluid Health<\/h2>\n\n\n\n<h3>What pH measures<\/h3>\n\n\n\n<p>pH describes how acidic or alkaline the fluid is on a 0 to 14 scale. Water-miscible coolants are built to run mildly alkaline, commonly somewhere between the mid-8s and mid-9s, because that range supports skin health, and corrosion protection on ferrous metals and makes the fluid less hospitable to bacteria. Some products are intentionally formulated lower for aluminum and other sensitive alloys, which is why<a href=\"https:\/\/www.masterfluids.com\/blog\/2020\/01\/22\/caring-for-your-coolant-best-practices-to-improve-the-life-of-your-metalworking-fluid\/\"> Master Fluid recommends checking each coolant against its own recommended pH range<\/a> instead of applying one number to every sump. The data sheet for your product is the reference point.<\/p>\n\n\n\n<h3>How to take a reliable pH reading<\/h3>\n\n\n\n<p>Indicator strips are quick and cheap, but they are only accurate to roughly a full pH unit, which is too coarse to catch early drift. A handheld pH meter calibrated before each round of readings gives you the tenths you need to see a trend. Calibrate with buffers that bracket your working range (pH 7 and pH 10 buffers suit most alkaline coolants), rinse the probe between sumps, and pull the sample from a running nozzle so you are testing circulating fluid and not the stagnant layer at the sump surface.<\/p>\n\n\n\n<h3>How often to check pH<\/h3>\n\n\n\n<p>Weekly readings are a sensible baseline for individual machine sumps. Central systems, sumps with a history of odor or rust, and machines coming back from a shutdown deserve readings two or three times a week until they settle. Record the value alongside concentration on the same day, because a pH change only makes sense when you know whether concentration moved with it.<\/p>\n\n\n\n<h3>What changes in pH may indicate<\/h3>\n\n\n\n<p>A gradual decline is the pattern to watch most closely. Bacteria feed on the fluid and<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/faqs.php\"> <\/a><a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/faqs.php\">release acids and salts that pull pH down and erode corrosion protection<\/a>, so a steady slide with stable concentration usually points to biological activity. The same downward trend with falling concentration is more often a lean-mix problem, and fixing the concentration frequently brings pH back on its own. A sudden rise tends to have a chemical cause, such as alkaline floor cleaner or parts-washer solution finding its way into the sump, or a sump that has been topped off too rich. High pH carries its own risks, since it increases the risk of skin irritation for operators and can stain aluminum and attack yellow metals.<\/p>\n\n\n\n<h2>Conductivity Testing: Tracking Dissolved Solids and Water Quality<\/h2>\n\n\n\n<h3>What conductivity measures<\/h3>\n\n\n\n<p>Conductivity measures how easily an electrical current passes through the fluid, reported in microsiemens per centimeter (\u00b5S\/cm). The number rises with the amount of dissolved, charged material in the sump: minerals from mix water, salts, dissolved metals, and the ionic components of the coolant concentrate itself. Because the concentrate contributes to the reading, a fresh charge has its own normal conductivity, and that starting value becomes the baseline for every later comparison.<\/p>\n\n\n\n<h3>Why water quality shows up in this number<\/h3>\n\n\n\n<p>With most water-miscible fluids running well under 10% concentrate, the water is by far the largest ingredient in the sump. Every gallon lost to evaporation leaves its minerals behind, and every top-off with hard tap water adds more. Maste<a>r <\/a>Fluid&#8217;s <a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/technical-bulletin.php?tbid=044\">Technical Bulletin #044 on metalworking fluids and water quality<\/a> explains how calcium and magnesium react with emulsifiers and corrosion inhibitors, which can split emulsions, form sticky residues, and weaken rust protection. The same bulletin notes that once water hardness passes roughly 5 to 7 grains, better-quality mix water starts to pay for itself, with savings of around 0.5% to 1% of concentrate for each grain of hardness removed. Conductivity is the simplest ongoing check on whether that dissolved load is building.<\/p>\n\n\n\n<h3>How often to check conductivity<\/h3>\n\n\n\n<p>A weekly reading taken with the pH check is enough for most sumps. It is also worth testing the incoming mix water whenever a new sump is charged, after any change in water source or treatment equipment, and once a month for plants that rely on reverse osmosis or deionized water, since a failing membrane or exhausted resin bed shows up quickly as a higher reading at the tap.<\/p>\n\n\n\n<h3>What changes in conductivity may indicate<\/h3>\n\n\n\n<p>A slow, steady climb over weeks with stable concentration usually means dissolved solids are accumulating from evaporation and hard makeup water. A sharp jump between two readings suggests something entered the sump, such as cleaner carryover from a parts washer, heat-treat or plating salts on incoming parts, or a batch mixed with the wrong water. When high conductivity coincides with rust complaints, dissolved salts deserve a close look, since<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/faqs.php\"> <\/a><a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/faqs.php\">dissolved salts from plant water, heat-treating, and plating are listed among the common contributors to corrosion<\/a>. Conductivity cannot tell you which ions are present, which is one of the clearest reasons to send a laboratory sample once the trend becomes a problem.<\/p>\n\n\n\n<h2>Microbial Counts: Measuring Biological Activity in Coolant<\/h2>\n\n\n\n<h3>What microbial testing measures<\/h3>\n\n\n\n<p>Water-miscible fluids contain water, oil, and organic additives, which together make a workable food source for bacteria, yeasts, and molds. Microbial testing estimates how many of those organisms are growing in the fluid. The most common shop method is the dip slide, a plastic paddle coated with culture media, usually with a bacteria side and a fungi side. Results are expressed in colony-forming units per milliliter (CFU\/mL) and read by comparing the incubated slide against the supplier&#8217;s chart.<\/p>\n\n\n\n<h3>How to run a dip slide correctly<\/h3>\n\n\n\n<p>Pull the sample from a running nozzle, immerse the slide fully for about ten seconds, let excess fluid drain, and return it to its tube. Bacteria typically need 24 to 48 hours of incubation, while yeasts and molds grow more slowly and can take several days to read accurately. Incubating at a steady temperature matters more than most shops expect, because a slide left on a cold shelf will undercount and give false comfort. Label every slide with the machine, date, and concentration reading so the result can be matched to the rest of that day&#8217;s data.<\/p>\n\n\n\n<h3>How often to test<\/h3>\n\n\n\n<p>The UK Health and Safety Executive&#8217;s widely referenced guidance calls for<a href=\"https:\/\/www.hse.gov.uk\/metalworking\/bacterial.htm\"> <\/a><a href=\"https:\/\/www.hse.gov.uk\/metalworking\/bacterial.htm\">dip slides once a week, with a lower frequency justified only by records showing that fluid management is under control<\/a>. A practical schedule for many shops is weekly slides for central systems and problem machines and every two to four weeks for stable individual sumps. Any machine that develops an odor, loses pH, or returns from a shutdown should get a slide right away.<\/p>\n\n\n\n<h3>What microbial counts may indicate<\/h3>\n\n\n\n<p>HSE classifies results below 10^4 CFU\/mL as good control, 10^4 up to 10^6 CFU\/mL as reasonable control that calls for checking and correcting fluid parameters, and 10^6 CFU\/mL or higher as poor control where draining and cleaning is normally warranted. The trend is often more useful than any single result. Counts that rise by one step on the chart from one week to the next, especially alongside falling pH, show a population that is outpacing the fluid&#8217;s defenses. Rotten-egg odors after a weekend point toward<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/technical-bulletin.php?tbid=066\"> anaerobic bacteria<\/a> living under a tramp oil layer, and Master Fluid Solutions has published guidance on<a href=\"https:\/\/www.masterfluids.com\/blog\/2020\/04\/14\/how-to-prepare-your-sump-for-a-temporary-shutdown\/\"> preparing a sump for a temporary shutdown<\/a> to prevent exactly that. A rise on the fungal side is worth taking seriously even when bacteria look fine, because fungal mats clog filters, lines, and nozzles and are harder to clear than bacterial growth.<\/p>\n\n\n\n<h2>Metalworking Fluid Testing Schedule at a Glance<\/h2>\n\n\n\n<p>The schedule below is a practical starting point for water-miscible coolants. Adjust it to your product data sheet, your risk assessment, and the history of each machine, and tighten it for any sump that is trending in the wrong direction.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Test<\/strong><\/td><td><strong>Typical tool<\/strong><\/td><td><strong>Individual machine sumps<\/strong><\/td><td><strong>Central systems<\/strong><\/td><td><strong>Also test when<\/strong><\/td><\/tr><tr><td>Concentration<\/td><td>Refractometer, confirmed by titration<\/td><td>Daily to 2x per week<\/td><td>Daily<\/td><td>After every top-off or recharge<\/td><\/tr><tr><td>pH<\/td><td>Calibrated handheld meter<\/td><td>Weekly<\/td><td>2 to 3x per week<\/td><td>Odor, rust, or residue complaints<\/td><\/tr><tr><td>Conductivity<\/td><td>Handheld conductivity meter<\/td><td>Weekly<\/td><td>2 to 3x per week<\/td><td>Water source or treatment changes<\/td><\/tr><tr><td>Microbial count<\/td><td>Bacteria and fungi dip slides<\/td><td>Every 2 to 4 weeks, weekly if unstable<\/td><td>Weekly<\/td><td>Odor, pH drop, or return from shutdown<\/td><\/tr><tr><td>Tramp oil and appearance<\/td><td>Visual check, settling test<\/td><td>Daily walk-by<\/td><td>Daily<\/td><td>Hydraulic or way-lube leaks<\/td><\/tr><tr><td>Full laboratory analysis<\/td><td>Supplier technical lab<\/td><td>Quarterly or when trends conflict<\/td><td>Monthly to quarterly<\/td><td>Any unexplained failure<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Keeping every reading on one sheet, or in a run chart such as the downloadable<a href=\"https:\/\/pdocs.masterfluids.com\/mcc\/download\/doc_download.php?f=\/db-docs\/tx-en-US\/TRIM-RUN-CHART-set.xltm&amp;t=tx\"> <\/a><a href=\"https:\/\/pdocs.masterfluids.com\/mcc\/download\/doc_download.php?f=\/db-docs\/tx-en-US\/TRIM-RUN-CHART-set.xltm&amp;t=tx\">TRIM Run Chart<\/a>, is what turns individual numbers into trends a team can act on.<\/p>\n\n\n\n<h2>Diagnostic Table: What Changing Readings Usually Mean<\/h2>\n\n\n\n<p>Single readings rarely diagnose anything on their own. The value comes from reading concentration, pH, conductivity, and microbial counts together and asking which combination you are looking at. The patterns below are the ones maintenance teams see most often, along with the likely cause and a sensible first response.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Pattern across readings<\/strong><\/td><td><strong>Likely cause<\/strong><\/td><td><strong>First response<\/strong><\/td><\/tr><tr><td>pH drifting down week over week, concentration stable, bacteria rising, odor after idle periods<\/td><td>Biological activity<\/td><td>Remove tramp oil, keep fluid circulating, retest with a dip slide, and ask your supplier about additive or biocide treatment; drain and clean at 10^6 CFU\/mL or above<\/td><\/tr><tr><td>pH and concentration falling together, microbial counts normal<\/td><td>Concentration drift (running lean)<\/td><td>Correct the mix, check proportioner settings, and confirm the true concentration by titration<\/td><\/tr><tr><td>Concentration, pH, and conductivity all creeping upward<\/td><td>Evaporation combined with overly rich makeup<\/td><td>Lower the makeup ratio using the<a href=\"https:\/\/apps.masterfluids.com\/makeup\/?r=NA\"> <\/a><a href=\"https:\/\/apps.masterfluids.com\/makeup\/?r=NA\">Coolant Makeup Calculator<\/a> and top off more often in smaller amounts<\/td><\/tr><tr><td>Conductivity climbing steadily, concentration stable, scum, residue, or foam changes<\/td><td>Water quality (hardness and dissolved solids)<\/td><td>Test the incoming mix water, review water treatment, and send a sample to confirm hardness and chlorides<\/td><\/tr><tr><td>Sudden jump in pH and conductivity between two readings<\/td><td>Chemical contamination such as alkaline cleaners or washer carryover<\/td><td>Trace the source, stop the ingress, and send a laboratory sample before adding correctives<\/td><\/tr><tr><td>Refractometer reads normal or high, but tool life, finish, or rust protection is slipping<\/td><td>Tramp oil inflating the reading<\/td><td>Titrate to find the real concentration and remove tramp oil with skimmers, coalescers, or<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/products\/show-category.php?catid=C15C\"> <\/a><a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/products\/show-category.php?catid=C15C\">separators and centrifuges<\/a><\/td><\/tr><tr><td>Rust appearing with concentration on target and low microbial counts, pH slowly sagging<\/td><td>Additive depletion, often corrosion inhibitors or total<a href=\"#_msocom_8\">[EH8]<\/a>&nbsp;alkalinity<\/td><td>Send a laboratory sample and follow the supplier&#8217;s recommendation for<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/products\/show-category.php?catid=B3B\"> <\/a><a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/products\/show-category.php?catid=B3B\">additive<\/a> replenishment<\/td><\/tr><tr><td>Bacteria acceptable, fungal side rising, clogged filters or nozzles<\/td><td>Fungal growth<\/td><td>Treat as recommended by your supplier and inspect lines and filters for mats<\/td><\/tr><tr><td>Counts return to high levels within weeks of a recharge<\/td><td>Biofilm left in the machine or plumbing<\/td><td>Perform a full clean-out with a<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/products\/show-category.php?catid=C24C\"> <\/a><a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/products\/show-category.php?catid=C24C\">machine maintenance cleaner<\/a> before recharging<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Use the table to decide where to look first. When two plausible causes fit the same readings, or when a correction does not move the numbers within a week or two, a laboratory sample will settle the question faster than further trial and error.<\/p>\n\n\n\n<h2>When to Send a Metalworking Fluid Sample to a Laboratory<\/h2>\n\n\n\n<p>Shop tests are good at flagging that something has changed, and a laboratory analysis goes further by identifying what changed and why, using methods a handheld meter cannot replicate, such as identifying specific dissolved ions, measuring tramp oil content, checking total alkalinity, and quantifying dissolved metals. A lab sample is the right next step in any of these situations:<\/p>\n\n\n\n<ul><li>Microbial counts stay at or above 10^6 CFU\/mL after concentration and pH have been corrected, or return quickly after a clean-out.<\/li><li>Readings conflict, for example a refractometer showing on-target concentration while machining performance or corrosion protection says otherwise.<\/li><li>Rust, staining, residue, or foam appears and the in-house readings look normal.<\/li><li>Conductivity climbs without an obvious cause, or the plant changes its water source or treatment system.<\/li><li>A central system is approaching a dump-and-recharge decision, where the cost of a new charge justifies confirming that the fluid cannot be recovered.<\/li><li>The shop grinds carbide, where<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/faqs.php\"> Master Fluid recommends regular testing to monitor dissolved cobalt levels<\/a>.<\/li><li>A new fluid has just been charged after a coolant conversion, so the team has a laboratory baseline to compare against.<\/li><\/ul>\n\n\n\n<p>Sample quality decides how useful the results will be. Master Fluid&#8217;s\u00a0<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/how-to-send-samples-to-mfs.php\">instructions for sending a sample<\/a> call for one pint of fluid collected in a clean, dry bottle from a running coolant nozzle or hose, labeled completely, and shipped to the Technical Services Laboratory in Perrysburg, Ohio. Depending on the analysis requested, results are typically released within two days of receipt. The report covers pH, conductivity, tramp oil percentage, bacterial levels, and concentration by refractive index, and a distributor coolant specialist or Master Fluid District Sales Manager can walk your team through what the numbers mean for that specific machine.<\/p>\n\n\n\n<h2>Turning Readings Into a Fluid Management Program<\/h2>\n\n\n\n<p>The shops that get the longest sump life from their coolant tend to share a few habits. They assign ownership of the test sheet to a named person on each shift; they record concentration, pH, conductivity, and microbial results on the same page for the same machine, and they agree in advance on the reading that triggers each response. That last habit matters most, because a written action limit removes the guesswork that otherwise lets a drifting sump run another month.<\/p>\n\n\n\n<p>The financial case builds quickly once readings are trended. Every correction made at the first sign of drift is cheaper than a dump, a clean-out, lost machine hours, disposal fees, and a full recharge of concentrate. Tighter concentration control reduces concentrate consumption, better mix water stretches every drum further, and stable fluid protects tools and finished parts from the scrap and rework that follow a failed sump. Master Fluid&#8217;s<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/case-studies\/list.php\"> case studies<\/a> document what those savings have looked like in real plants across industries.<\/p>\n\n\n\n<p>For teams that want help building or auditing a testing routine, contact <a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/company\/contact_us.php?o=MCC\">Master Fluid<\/a> and a fluid expert will contact you.\u00a0 The broader<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/metalworking-fluids.php\"> Metalworking Fluids Guide<\/a> and<a href=\"https:\/\/www.masterfluids.com\/na\/en-us\/technical-information\/metalworking-fluids-glossary.php\"> glossary<\/a> are useful references for training new technicians on the terms used throughout this article. A fluid that is measured consistently is a fluid a team can plan around, and that predictability is where most of the cost savings come from.<\/p>\n\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Most coolant sumps give plenty of warning before they fail. The pH slides a few tenths over three weeks, conductivity creeps upward after every top-off, and a dip slide that used to come back clean starts showing colonies. By the time anyone notices a rotten-egg smell on Monday morning or rust spotting on finished parts, the fluid has usually been in trouble for a while, and the cheapest window to fix it has already closed.<\/p>\n","protected":false},"author":5,"featured_media":1495,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"off","_et_pb_old_content":"","_et_gb_content_width":""},"categories":[2],"tags":[],"_links":{"self":[{"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/posts\/1494"}],"collection":[{"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/comments?post=1494"}],"version-history":[{"count":1,"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/posts\/1494\/revisions"}],"predecessor-version":[{"id":1496,"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/posts\/1494\/revisions\/1496"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/media\/1495"}],"wp:attachment":[{"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/media?parent=1494"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/categories?post=1494"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.masterfluids.com\/blog\/wp-json\/wp\/v2\/tags?post=1494"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}